Don’t turn anything on or off, including light switches. Open windows and doors to ventilate the property, and turn the gas off at the meter if it’s safe to reach.
Leave the property and call the National Gas Emergency line on 0800 111 999 — free, 24 hours a day. Please don’t call us first for a suspected gas leak — they’re the right people to make it safe.
Most combi and system boilers have a built-in filling loop. Pressure should sit between 1.0 and 1.5 bar on the gauge when the boiler is cold.
To top up: turn the boiler off and let it cool. Find the filling loop — usually a silver braided flexible hose underneath the boiler, with two small valves at each end. Open both valves slowly while watching the gauge, and close both firmly once it reaches around 1.2 bar.
Don’t go above 2.5 bar — the pressure relief valve will discharge water through the outside pipe. If pressure keeps dropping after topping up, there’s likely a leak in the system — give us a call.
Trapped air. Turn the heating off and let the radiators cool. Put a small towel under the bleed valve at the top corner of the radiator and use a radiator key — quarter turn anti-clockwise. You’ll hear air hiss, then water will trickle out. Close the valve as soon as water appears.
Bleeding lowers the system pressure, so check the boiler gauge afterwards and top up if needed (see above).
If the water coming out is dirty brown, the system likely has sludge — that needs a chemical or power flush, which we can sort.
Common during cold snaps. The condensate is a white plastic pipe (usually 22mm) running from the boiler to an outside drain. When it freezes the boiler locks out.
To thaw it: pour warm — not boiling — water along the outside section, focusing on bends and the open end. A warm towel wrapped round the pipe works too. Reset the boiler once thawed.
To stop it happening again, lag the outside pipe with foam pipe insulation.
The main stopcock is usually under the kitchen sink, or near where the cold water supply enters the property (sometimes a downstairs cupboard or by the front door). Turn it clockwise to close.
Don’t force a stiff stopcock — older ones can seize and snap. If yours won’t budge, leave it alone and call us.
For local isolation, look for small isolation valves on the supply pipe to individual appliances — under sinks, behind toilets, at washing machines. They take a slotted screwdriver, quarter turn.
Worth finding your stopcock before you need it in an emergency.
One reset attempt is fine — sometimes a boiler trips after a brief glitch and a single reset clears it.
If it locks out again straight away, don’t keep pressing reset. The boiler is telling you something needs a proper look, and on some models repeated resets can cause damage. Call us and we’ll diagnose what’s going on.
Usually limescale build-up in the heat exchanger, or sludge circulating through the system. It won’t stop on its own.
Short-term: turn the central heating temperature down a notch — that can reduce the noise.
Long-term: it usually needs a chemical or power flush, and a magnetic filter fitted on the return to catch debris before it causes damage. Book it in.
First check the boiler is set to allow hot water — some models have a summer/winter mode selector or a separate hot-water enable button.
If the boiler doesn’t fire when you turn on a hot tap, the most common cause is a sticking or worn diverter valve, which needs an engineer. Give us a call.
Run through these in order:
1. Is the programmer/timer actually calling for heat?
2. Is the room thermostat set above the current room temperature?
3. Are the thermostatic radiator valves (TRVs) on the radiators open?
4. Bleed any cold radiators (see above).
5. Check the boiler pressure (see above).
If all of that’s fine and the boiler still won’t fire for heating, call us.